Breakers go bad sometimes, after many years. },
Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. I have a PF1112T. If power is coming to the timer motor, you will clearly see the gears moving through the small window. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. Turn on / off manually work fine, but The clock gears still not moving. {
Hi Sam, check that the dial is not warped or bent, the yellow clock dial. It was always fine before. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. Ive got the opposite problem than a lot of people. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Could I send you a picture of my setup? This will disengage the dial from the . Other causes include rusted springs, insect infestation and loose timer dogs. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Any ideas why its doing that? What Im wanting to do is just disable the turn off/on and just keep power 24/7. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. Can breaker be bad? After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Articles and resources for swimming pool owners and DIYers. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Sometimes those are looped back to the control box. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? It should sit down nicely. Hi Davey, These clocks determine when your pool pump turns on, and how long it runs. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Check that dial is not warped. More. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. A wire inside the motor may be touching another wire, or the metal sides of the motor. Pool pump comes on fine with the on dog, but wont turn off. That way I could schedule the pump once again. Found the answer. Check the motor, and be sure the label is not printed 50 hz. A recent power outage will cause the timer to stop working. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. They should be straight, if not, replace them. 2. I think I have found it. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Proceed to step 4 to check the timer itself. This site is owned and operated by AJH Trade Group. . Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. These are the trippers that came with the time clock. You will first need to adjust the time on the timer first. The pool timers I have had down there . Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. It is an ON tripper right? charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. I have a white, red, and black wire coming from the power source. Theres an issue with the wiring between the circuit breaker and the timer. It would not reset itself and could not get power back to the timer. Jul 20, 2021. I bought a new motor for mine after 20 years and learned about this the hard way. You need extreme care in this next step. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. My timer clock does not run and the manual on off switch does not turn off the pump motor. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. Hi Casey, perhaps the cord or wires are broken? The timer appears to be working fine (keeps time). I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. If you use our referring links, it costs you nothing extra. Replaced complete new timer assuming 5 years perfect service probably wore it out. If any of these issues occur your timer will not work properly. Hello, newer pool guy here. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. 120Volt Tork 1101 timers can be fixed with repair parts. Did you find the issue? I used to run the pump for 8-9 hrs a day. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. Timer not tripping pump on. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. You should be able to see the gears moving. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. It should be 110V or 220V AC. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. If you cant see an issue with the gears, then it could be the timer motor. Hi Bev, seems legit to me! Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? },
4 Beds. "dateModified": "1/10/2020",
You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. Save my name, email, and website in this browser for the next time I comment. Off flipper always works. This will disengage the dial and allow you to spin it in either direction. But no gears or any sound. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Voltage is 243, frequency is 60hz. Turn in either direction and align the exact time-of-day on . Replace a new T104. The most common pool timer used for inground pool pumps is the Intermatic time clock. Almost like it doesnt have the strength to click the timer on or off. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. I bought a new timer and replace the T104 timer clock. The problem lies where the power dies, youve probably heard that before. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. Is this a bad timer mechanism or loose wire? The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. When I put the new one on, the trippers do not work. When you flip the switch does it separate and reconnect the tabs? For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Hi Carlos, is there a GFCI outlet in the circuit? Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. March 16, 2022 by WildRiverCountry. Pools are not cheap! Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. If its not, then the timer will not turn on/off at the correct times. I noticed that they had stopped. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Now it worksbut its really fast. Back when I was a young technician I was taught to always look for the easy things and use all my senses. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
1. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
As an Amazon Associate we earn from qualifying purchases. It just seems to have a weak start?? A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. do i need to do something different? Ordered new ones. If not, the motor may be failing. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. I guess if they look the same as before maybe the dial is warped? But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Wont power on pump but can hear timer clicking away. Or other advice or explanation. Is it possible to do this by loosening the timer screw a bit? Or may be bent and not come together. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Did I wire it incorrectly or did I just get a bad timer? Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Is the ON tripper all the way pushed onto the dial? Keeping a pool operational is expensive enough anyway, so every saving you can make helps. ft. home is a 3 bed, 4.0 bath property. Simply screw it back into place until its snug. Now remove the terminal cover on the timer. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Reference Manual & Buyer's Guide Another Brick in the If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Make sure the middle time pointer is tight. The same happens prior to the timer reaching the off tripper. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). My intermatic timer is about two years old as well. Donna Simpson Eating Website But What Toilet? Second thing to check is the dial bent or warped, in that area where the on tripper is? Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. After a power failure the timer clock can start up backwards, mine has done this several times. Could also be grit or insects inside of the gears of the clock motor. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
I have a 2 speed pump. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. Hi there, Yes, likely a short to ground. But my new timer will not work either. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing.