The UT55A/UT52A also support open networks such as Ethernet communication. switch is a device for turning off the power to the instrument. 1.Do not run input wires together with power cables. When installing the TC10, what is the depth in millimeters from the surface of the panel? The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. When the maximum front protection (IP65) is. IP65 Certification when the optional panel gasket is mounted. What is the measured current of the TC10's RTD input? Do I need a minus sign ( - ) on the alarm setting value? Type: Instructions manual . A ladder sequence function is included as standard. . Case: Plastic, self-extinguishing degree: V-0 according to UL 94, Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1, Terminals protection: IP 20 according to EN 60070-1, Terminal block: 16 screw terminals for cables of 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm, Dimensions: 48 x 48, depth 62 mm (1.89 x 1.89 x 2.87 in. The UT35A/UT32A also support open networks such as Ethernet communication. Third edition: Feb. 2018. . 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. Moreover, provide indication that the. AL on the front of the TC10 is the alarm lamp. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. condensation); 5. use only, in an electrical panel which encloses the rear housing. External components (like zener barriers, etc.) period. exposed terminals and wiring on the back. Do not run input wires together with power cables. View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals A ladder sequence function is included as standard. Note: During the test, the instrument continues to operate at the measurement accuracy within specication. 2 Cold junction accuracy:0.05C/C after a warm-up of 20 minutes. the protection provided by this instrument may be impaired. Yokogawa Electric Corporation for this Product in the EEA. When you do this, the upper limit range of 1000C becomes 999.9C. The 3-year warranty extends 36 months after shipment from our factory. 2. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not, For measurements performed on circuits directly. requirements of the area in which the instrument is being installed. YOKOGAWA TC10-L: Quick Manual| Brand: Want to have your manuals available on hand: always and everywhere? IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. exposed terminals and wiring on the back. 0/4 to 20 mA input wiring for passive transmitter using the auxiliary pws. 5, the lower display is showing its value, this key allows, to store the selected value for the current parameter. The shallow depth of the controller helps to save instrument panel space. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. For complete controller configuration see the Engineering Manual. - Modification of the product is strictly prohibited. 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). Only wire the other instruments SG terminal. There is minimum vibrations and no impact; There are no water or other uids (i.e. Yes, by changing the DP setting from 0 to 1. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. When you do this, the upper limit range of 1000C becomes 999.9C. future reference. Is there a controller to which I can connect a 2-wire Pt1000 sensor? SSR outputs are not isolated. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. Current availability for non-stock parts is "Usually ships in 7-10 business days". equipment and devices that ensure personnel safety. Notes: 1. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. 1 to 4 indicate the status of outputs 1 to 4. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). Nadcap AMS2750F - What's New and How to Comply? - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. NOTE: This parameter will be shown only when a linear input has been selected (mV, V or mA). be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Notes: 1. If this instrument is used in a manner not specified in this manual. There are no water or other uids (i.e. Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. D + D - D + D - D + D - D + D - RS-485 5 6 - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. The ambient temperature is in accordance with the operative, 6. [4]FSc - Full scale read-out for linear input. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. 2. Model: TC10 - Quick Guide . can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. Pages: 30 . TC10 does not come with a terminal cover. Search the full list . The TC10 supports easy configuration for quick start-up, and itsPID allows for overshoot andundershoot control, so the end user can maintain a direct and constant temperature or accurate flow. Assign OP4 to the control output operation. - Modification of the product is strictly prohibited. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. In other words the upper display will show: ]INP. Brand: YOKOGAWA . 2.Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. With the /GK suffix, the TC10 supports the IP65. The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Download Manual of YOKOGAWA TC 10-L Controller for Free or View it Online on All-Guides.com. The UT32A-D is a compact digital indicating controller with selectable 2-loop control. Relay output 2,3: 2A, 250 V AC, resistive load. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. that no power is being supplied to a cable to be connected. Approximately 2 seconds or less. View and Download Yokogawa TC10-L instruction manual online. YOKOGAWA Accessory Manuals 12 Devices / 14 Documents Full list of YOKOGAWA Accessory Manuals YOKOGAWA AC Power Distribution Manuals 1 Devices / 1 Documents YOKOGAWA Adapter Manuals 9 Devices / 10 Documents Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. Notes: 1. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. I'm sending the temperature via PV transmission on TC10. The TC10 supports easy configuration with codes for quick start-up. Use a tester or similar device to ensure. Yokogawa TC10-L Manual Download for 1 TCTC10- L LIMIT CONTROL TYPE Engineering Manual Code: IM 05C01E81-12EN First edition: Nov. 2019 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. Copyright 1994-2023 Yokogawa Corporation of America, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type). Input impedance:> 1 M. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 Push button for more than 3 seconds, the instrument will come back to the standard display. 1. A ladder sequence function is included as standard. Temperature drift: It is part of the global accuracy; Operating temperature: 0 to 50C (32 to 122F); Storage temperature: -20 to +70C (-4 to +158F); Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. 2. suit your application (e.g. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. For measurements performed in the building, For measurements performed at the source of, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. There is no parameter for specifying the output direction. exposed terminals and wiring on the back. 4 2.4 SERIAL INTERFACE. The ambient temperature is in accordance with the, 6. Backed by the high reliability and quality that Yokogawa has cultivated over many years. When a shielded cable is used, it should be connected at, 4. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. WARNING! CONTROLLER Engineering Manual. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. use only, in an electrical panel which encloses the rear housing. 2.External components (like zener barriers, etc.) Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. I want to use the detailed parameter setting method of TC10, but what number is the password? Input circuit: Current injection (135 A). SKU:WE4537266 The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. The TC10 is a compact single loop temperature controller with an easy-to-read 3-color LED display. View online Manual for YOKOGAWA TC 10-L Controller or simply click Download button to examine the YOKOGAWA TC 10-L guidelines offline on your desktop or laptop computer. The conguration parameters are collected in various groups. Supply Voltage: 100 to 240 VAC (-15 to +10%). Model: TC10 - Quick Guide . Pay attention to the line resistance; a high line resistance may cause measurement errors. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. With thermocouple K input, can I display digits after the decimal point for the temperature? fail to observe these instructions when operating the product. If so used, it is the user's responsibility to include in the system additional. equipment and devices that ensure personnel safety. Set detailed parameter out group o1.F (output 1 function) = r.inP. Other part numbers are available to order but are not currently in stock. Yokogawa Electric Corporation for this Product in the EEA. WARNING! The. Note: This filter will affect the measured value but also the control action the analogue retransmission and the alarms, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. Controller YOKOGAWA . condensation); The ambient temperature is in accordance with the operative temperature (0 to 50C); The relative humidity is in accordance with the instrument specications (20 to 90%); Do not run input wires together with power cables. condensation); 5.The ambient temperature is in accordance with the operative temperature (0 to 50C); 6.The relative humidity is in accordance with the instrument specications (20 to 90%); The instrument can be mounted on panel with a maximum thickness of 8 mm. of use, service life and misuse are not covered by this warranty. Note: The complete list of the default parameters is available in Appendix A. Does the TC10 come with a terminal cover? The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. I'm sending the temperature via PV transmission on TC10. To avoid electrical shocks, connect power line at last. A ladder sequence function is included as standard. connected to the low-voltage installation. and workmanship for 18 months from the date of manufacturing. mA output: 0/4 20 mA, galvanically isolated, RL max. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. Products and components that are subject to wear due to conditions. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. A reinforced isolation must be assured by the external solid state relays.