However, the more advanced problems will most likely need a licensed plumber. Anyway,the process to test your own thermopile is relatively simple. You may have to dim the room lights to see the spark. All Right Reserved by FIREPLACEHUBS. Now learn all the probable reasons in detail and how to break down the culprits with ease by following the suggested methods. If the spark electrode wont produce a spark, the electrode itself is likely defective and needs replacing. If you doing any soldering, make sure to wear protective eyewear. Remove the front access panel of your water heater. If it isn't flowing, replace the SmartValve. If youre having trouble getting your water heater to light its pilot light, first check the following spark electrode for dirt and corrosion since this could be your problem. Detach both igniter wire and the thermocouple wire that leads into the gas control valve. When troubleshooting your hot water heater, check to ensure that the correct voltage is reaching your gas valve. There are several factors for continuously tripping the thermal switch. And you will surely learn to fix your Honeywell heater issues by yourself. Thank for your feedback. The root reasons behind Honeywell hot water heater no status light includes: Furthermore, due to tripped thermal switch, lack of combustion air, and defective heater thermopile, owners will face no status light blinking issue on their water heaters. If still, you are hearing the beeping noise, then try to restart the system. Your Honeywell water heaters faulty gas valve will lead to different problems. Follow the solutions below and make sure your Honeywell heaters status light is blinking. The igniter itself when out of the control panel sparks fine but when connected it does not spark at all. If you move through this list, and still cannot find the problem, then you know it is time to call in a professional. Turn the thermostat to its lowest possible setting. However, your heater keeps shutting off mainly for the following reasons: To fix the above troubles; you need to check your heaters pilot light and thermocouple. So, you should replace it after every 7 years. Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. How to fix Honeywell water heater status light blinking 7 times, ii. The gas will need to disperse, and then you will be ready to try it again. Some people refer to this problem as a flare out or simply pilot failure. Therefore, you should always consult the instructions from your manufacturer. Attach the red positive lead to the red thermopile wire. Repair the damaged part as soon as possible. If none of these is the issue, it could be something more advanced, like a bad thermocouple. Continue with Recommended Cookies. Inspect the flex tube to test whether it is kinked from any portion. They contain scalding water that is under pressure, which can spray from the pressure-relief valve, putting nearby individuals at risk of burns. After going through our ultimate guide, already you know what are the common Honeywell water heater problems, their reason, and solutions. When this happens, your burners wont ignite, and your homes water will be freezing cold. That way, you can correct them and return your water heater to proper functionality. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. The water heaters safety devices are FV (Flammable Vapor) sensors. If its loose, broken, or damaged, fix all the issues. The thermocouple detects the pilot flame. A broken, bent, worn-out, damaged, or a faulty thermocouple, Properly clean the thermocouple, pilot tube, and clogged air inlet, Replace the bent, broken, or defective thermocouple, tripping breaker, faulty gas valve, and malfunctioning thermostat, Turn off your heaters gas connection and allow some time to cool the thermocouple. If you see below 400 millivolts, be sure it is defective. If the pilot does not light, the water heater will not heat up. Honeywell Water Heater Keeps Turning Off, 5. All Right Reserved by FIREPLACEHUBS. If you are unsure about what you are doing, do not hesitate to call a service professional. It will purge the air from the gas line. Then, clean out the flame arrestor using a household brush. Follow the below instructions: Step #1: First up, shut off the gas shut-off valve. The sediment contains different chemicals and salt. Go on reading our Honeywell water heater troubleshooting guide. How do I reset my Honeywell water heater? If there is no light, be sure dirt and debris have accumulated on the pilot assembly that is preventing lighting the burner. Check all wiring connections. Heater Knob Stuck 10. If so, simply straighten the kinked tube. This issue is most likely caused by one of the following: If your gas water heater has an electronic ignition system, you should never attempt to light it by hand. Check the T&P valve and verify whether it is in good working condition or not. Induced draft water heaters use an intermittent pilot or hot surface ignition instead of a standing pilot light. Some issues caused by a bad valve are gas leaks, heaters total shutdown, heater stops working, heater blinks error codes, etc. Its essential to regularly clean your water filter to avoid this issue, and if you find that its already clogged, youll need to replace it. Sometimes it may be an easy fix, such as a loose wire, other times, it may be something more advanced, such as a bad thermocouple. Ensure your heaters backdraft is not creating any pilot light issues. Last but not least, a bad thermopile is one of the major reasons behind the Honeywell hot water heater status light-off issue. If the Honeywell water heater light is not blinking, it may be due to a faulty light switch. Honeywell Water Heater Troubleshooting [11+ Easy Fixes] 1. Aside from all the above actions, you have to ensure proper gas pressure in your water. Interruption In The Gas Supply 4. Once heating is required, the gas control valve will discharge gas into the main burner and the pilot light will ignite the gas. 5 Flashes = Sensor Failure. A brief visual inspection will generally help you discover possible issues with your pilot flame. Learn more, Facebook II Twitter II Pinterest II Linkedin. 2 Flashs = Thermopile low voltage. If the flames color is red, yellow, green, or anything other than bright blue, this means that something else is inside of the gas and is burning along with the methane. If your water heater has a digital readout or an automatic reset thermostat, its likely working. Replacement is an easy DIY repair. Another common issue with the pilot light on water heaters is that the flame frequently goes out. Due to a loose connection of the connector, the red status light will not blink. 8 Flashes = Power off Failure. What will happen if the water heater gets a high-temperature shutdown? Change the defective elements of the system to prevent this problem. Lets look at some of the most common problems, so that we may find the solutions. In short, the igniter doesnt work if its wiring comes out of the white connector. When you click the igniter, you should hear a click sound, indicating the spark igniting the pilot. You can check the state of the igniter by inspecting if it is receiving voltage. The most common Honeywell water heater problems are the heater not heating or the heater keeps shutting off. Just follow the troubleshooting steps I mentioned and fix them. Another reason for water heater leaks is the tank not being properly sealed. Honeywell Water Heater Is Not Hot Enough, 3. In the next chapter, I will walk you through the step-by-step procedure of igniter replacement. The pilot light in your water heater is a small device that is designed to provide the flame to light the gas released out of the gas valve and main burner. Stick to the following steps to learn how to clean igniter on a water heater: If cleaning the thermopile doesnt bring any luck, I bet the igniter itself is the culprit. Clean out clogged debris from the vents using a vent cleaning brush and make them blockage-free. Thermal switchs loose wire lead connection, Clean the filthy pilot and tubes and gas line dirt, Replace the failed pilot light controller unit, malfunctioning thermopile, bad pilot tubes, wrong wiring, damaged flex tube, defective control valve, faulty pressure switch, spark electrode, and non-functioning igniter. Set the gas control knob to PILOT. She grew up surrounded by constant home improvement projects and owes most of what she knows to helping her dad renovate her childhood home. We will be happy to help you. An example of data being processed may be a unique identifier stored in a cookie. > Faulty thermostat knob, or gas control valve. Then, check and replace the bad gas control valve. Another solution is resetting the unit by pressing and holding down both buttons for three seconds. After resolving the pilot issue and there is still no blinking on the status light, a bad igniter or malfunctions from the igniter is the second suspect. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. Clean the pilot tube using a sharp object to remove the blockages. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Extracted igniter wires that come out of the white connector are the first I blame most. Most Honeywell water heaters with electric gas valves need just 12 volts for the valve to work. Due to this, the status light will not blink. Press and hold down on the gas control knob, or pilot set button. The other causes of it are: Your water heater can make different types of noises such as rumbling, banging, crackling, ticking, hissing, screeching, and popping. If the FV sensor detects any issue near the heater, it will prevent your heaters ignition possibility by going into lockout mode. What Are The Pros And Cons Of An Indirect Water Heater. Check out any corrosion in the connections. Hot water heaters are perhaps one of the most important things in our home. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-netboard-1','ezslot_24',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-netboard-1-0');A thermal switch is a safety device on a water heater. Finally, verify the igniter is working properly by relighting the pilot following the lighting instructions on the manual. Throughout this article, we have assembled all the aspects behind the Honeywell water heater status light not blinking issue. Just follow the below simple steps I described below to make the replacement correctly: First off, turn the main gas supply valve clockwise to stop the gas supply to the unit. Kit includes: piezo igniter and instructions; For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater